Heat pump not cooling
A heat pump that is not cooling most often has a thermostat setting wrong, a clogged filter, a tripped breaker or a dirty outdoor coil. If those check out, the likely causes are a failed capacitor, a refrigerant leak or a reversing valve stuck in heating mode. You can check settings, power and airflow. Refrigerant and valve problems need a licensed technician.
Safety first. Do not open the outdoor unit or handle refrigerant. If you see ice on the refrigerant lines or indoor coil, turn the system off and let it thaw before running it again.
Check these first
0 of 7 checkedStill not working after these? That is the point to bring in a licensed technician.
What it usually means
In cooling mode a heat pump works exactly like a central AC, so most of the causes are the same. The system needs three things to cool: correct instructions from the thermostat, enough air moving across both coils, and the right amount of refrigerant. When one of those is missing, the air from the registers turns lukewarm or the system runs all day without reaching the setpoint.
One cause belongs to heat pumps alone. The reversing valve decides whether the system heats or cools. If it sticks, the unit can blow warm air while the thermostat asks for cooling.
Likely causes, most common first
- Thermostat set wrong. Heat mode, fan set to On, a schedule override or dead batteries.
- Dirty filter or blocked vents. Low airflow cuts cooling and can freeze the indoor coil.
- Tripped breaker or drain safety switch. The indoor fan runs but the outdoor unit does not.
- Dirty outdoor coil. The unit cannot shed heat, so it runs hot and cools poorly.
- Failed capacitor or contactor. The outdoor unit hums, clicks or stays silent.
- Low refrigerant from a leak. Long run times, weak cooling and sometimes ice on the lines. The page on an AC refrigerant leak explains the signs and the repair, and it applies to heat pumps too.
- Reversing valve stuck in heat. Warm air in cooling mode with everything else running.
- Compressor failure. The least common and most costly cause.
Heat pump stuck in heat mode
If the system heats when you ask for cooling, rule out the thermostat first. A thermostat that was replaced or reconfigured can be set for the wrong reversing valve type, which swaps heating and cooling. Check the installer settings in the thermostat manual, or ask whoever installed it.
If the thermostat is right, the fault is in the valve circuit: the wire to the valve, the solenoid coil that shifts it, or the valve body. A solenoid coil is a modest repair. Replacing the valve itself means recovering the refrigerant, cutting the valve out, brazing in a new one and recharging the system, so it is one of the larger heat pump repairs. You cannot tell which of these it is without electrical and pressure tests.
What a technician will do
The tech will confirm the thermostat setup, measure voltage at the outdoor unit and at the reversing valve, test the capacitor and contactor, clean or inspect the coils, measure the temperature drop across the indoor coil and read refrigerant pressures. If the charge is low, a proper repair includes finding and fixing the leak before adding refrigerant. Ask for the findings and a written quote before work starts.
When it points to replacement
Settings, filters, capacitors and dirty coils are routine fixes. Think about replacement when the compressor has failed, when a coil is leaking, or when a reversing valve replacement is quoted on an older system that has already needed major work. Compare the repair quote with a replacement quote before deciding. The heat pump overview links to the cost and replacement pages.
Common questions
Why is my heat pump not blowing cold air when the fan is running?
The indoor fan can run while the outdoor unit is off. Check the outdoor breaker and listen for the compressor. If the outdoor unit is running and the air is still warm, the likely causes are low refrigerant, a dirty outdoor coil or a stuck reversing valve, and you need a technician.
What does the reversing valve do on a heat pump?
It changes the direction refrigerant flows, which switches the system between heating and cooling. A small electric solenoid shifts it when the thermostat changes modes. When the valve or its solenoid fails, the heat pump stays in one mode or gets stuck partway and does neither well.
Can a reversing valve be repaired, or does it need replacing?
If only the solenoid coil has failed, a technician can replace the coil without opening the refrigerant system. If the valve body is stuck or leaking internally, it has to be replaced, which involves recovering and recharging refrigerant. A tech has to test it to know which applies.
Is it safe to keep running a heat pump that is not cooling?
Running it for long with low airflow or low refrigerant can ice the coil and strain the compressor. If basic checks do not restore cooling, turn the system off, or run the fan only if you see ice, and schedule a service visit.
Related guides
Next step
Need it fixed today?
We are an independent guide for homeowners, not a contractor. When you ask, we work to connect you with one licensed company that serves your ZIP code.
HeatCoolVerdict is not a contractor. We connect you with licensed local companies, and they pay us when you call or request a quote. It does not change what you pay. How we make money
Get a repair pro on the phone
Tell us what is wrong and where you are. We will get back to you and connect you with a licensed local company.